Scissor lifts
JLG ES2632
Narrow (0.81 m) electric scissor lift with 10 m working height, for doorways and tight aisles.
- Working height
- 9.77 m
- Platform size
- 0.77 × 2.30 m

Electric scissor lift · 8 m
Compact 8 m electric scissor lift, 0.81 m wide: it fits through doors and corridors and is ideal indoors.
Also known as: ES1932
Official JLG dealer in Portugal · sales, parts and technical service
The JLG 1930ES is the compact 8 m electric scissor lift: 7.8 m working height in a machine 0.81 m wide and 1,565 kg that fits through doors, corridors and goods lifts.
JLG now builds this model as the ES1932; the specifications on this page are those of the current ES1932, slightly wider than the old 1930ES (0.81 m instead of 0.76 m).
It carries 230 kg (2 people indoors, 1 outdoors), has a 0.86 m deck extension and can drive fully elevated. Non-marking tyres, zero emissions and a zero inside turning radius: ideal for indoor maintenance, installation and finishing work.
Values from the manufacturer's European (CE) spec sheet. They can vary with the configuration and options.
The main specifications of the JLG 1930ES next to similar models.
| Specification | JLG 1930ES | JLG 3246ES | JLG 4394RT | JLG ES2632 |
|---|---|---|---|---|
| Working height | 7.8 m | 11.75 m | 15.11 m | 9.77 m |
| Platform size | 0.77 × 1.67 m | 0.95 × 2.12 m | 1.79 × 3.86 m (extensions retracted) | 0.77 × 2.30 m |
| Overall width | 0.81 m | 1.17 m | 2.31 m | 0.81 m |
| Platform capacity | 230 kg (2 persons indoor / 1 outdoor) | 320 kg indoor (2 persons) / 230 kg outdoor (1 person) | 568 kg (dual extension) / 682 kg (single extension) | 230 kg indoor (2 persons) / 125 kg outdoor (1 person) |
| Machine weight | 1,565 kg | 2,550 kg | 6,727 kg | 1,996 kg |
| Power | Electric, 24 V | Electric, 24 V | Diesel, Kubota 18.5 kW | Electric, 24 V |
Transport: 1,565 kg and 1.74 × 0.81 × 2.10 m (1.63 m with rails folded): it fits on a trailer or flatbed van with ramps and adequate payload.
Where it works: mainly indoors; outdoors with 1 person only. Maximum ground pressure is 8.01 kg/cm²: check the strength of raised floors and slabs. Gradeability 25%.
Batteries: four 6 V 213 Ah AGM batteries (24 V) with a 27 A automatic charger.
Operator: The operator must be properly trained to use mobile elevating work platforms (MEWPs): the employer is required to ensure this (Decree-Law 50/2005). The IPAF/PAL card is the most widely recognised training.
Inspections: Like any work equipment that lifts people, it needs mandatory periodic inspections (DL 50/2005), in addition to the manufacturer's preventive maintenance.
The price of a new JLG 1930ES is on request: it depends on the configuration (options, tyres, power, accessories), lead time and delivery location. Tell us what the machine is for and we will send a quote.
See used 1930ESSearch the code the machine shows to see what it means.
On machines equipped with the MDI (Multifunction Digital Indicator), DTCs are read on the MDI; DTCs are grouped by their first two digits, which are also the system distress lamp flash code shown on the platform control box. Flash codes and DTCs are also displayed on the handheld analyzer.
145 codes
| Code | Meaning |
|---|---|
| ERROR | ERROR (DISPLAYED ON MDI) |
| 0010-0 | EVERYTHING OK |
| 0020-0 | GROUND MODE OK |
| 0030-0 | ALARM SOUNDING – TILTED & ABOVE ELEVATION |
| 0040-0 | DRIVING AT CUTBACK – ABOVE ELEVATION |
| 0050-0 | DRIVE & LIFT UP PREVENTED – TILTED & ELEVATED |
| 0060-0 | LIFT UP PREVENTED – MAX HEIGHT ZONE A |
| 0070-0 | DRIVING AT CUTBACK – POTHOLE STILL ENGAGED |
| 0080-0 | FUNCTIONS LOCKED OUT – SYSTEM POWERED DOWN |
| 0090-0 | DRIVE PREVENTED – ELEVATED ABOVE DRIVE CUTOUT HEIGHT |
| 2112-1 | POWER CYCLE |
| 2122-1 | KEYSWITCH FAULTY |
| 2212-2 | FUNCTION PROBLEM – HORN PERMANENTLY SELECTED |
| 2222-2 | FUNCTION PROBLEM – INDOOR/OUTDOOR PERMANENTLY SELECTED |
| 2232-2 | FUNCTION PROBLEM – DRIVE & LIFT ACTIVE TOGETHER |
| 2242-2 | FUNCTION PROBLEM – STEER LEFT PERMANENTLY SELECTED |
| 2252-2 | FUNCTION PROBLEM – STEER RIGHT PERMANENTLY SELECTED |
| 2262-2 | ACCELERATOR FAULTY – WIPER OUT OF RANGE |
| 2272-2 | STEER SWITCHES FAULTY |
| 2282-2 | FUNCTION LOCKED OUT – ACCELERATOR NOT CENTERED |
| 2292-2 | FUNCTION PROBLEM – TRIGGER PERMANENTLY CLOSED |
| 22102-2 | TRIGGER CLOSED TOO LONG WHILE IN NEUTRAL |
| 22112-2 | FOOTSWITCH CLOSED TOO LONG WHILE IN NEUTRAL |
| 22322-2 | FUNCTION PROBLEM – DRIVE & LIFT BOTH OPEN |
| 2312-3 | FUNCTION PROBLEM – LIFT PERMANENTLY SELECTED |
| 2322-3 | GROUND LIFT UP/DOWN ACTIVE TOGETHER |
| 2332-3 | FUNCTION PROBLEM – BRAKE RELEASE PERMANENTLY SELECTED |
| 2512-5 | ELEV ANGLE SENSOR FAULTY – VOLTAGE OUT OF RANGE |
| 2522-5 | ELEV ANGLE SENSOR HAS NOT BEEN CALIBRATED |
| 2532-5 | DRIVE PREVENTED – CHARGER CONNECTED |
| 2542-5 | DRIVE & LIFT UP PREVENTED – CHARGER CONNECTED |
| 2552-5 | PLATFORM OVERLOADED |
| 2562-5 | DRIVE PREVENTED – POTHOLE NOT ENGAGED |
| 2572-5 | ELEV PROX PERMANENTLY CLOSED – CHECK PROX AND ANGLE ADJUSTMENT |
| 2582-5 | DRIVE & LIFT PREVENTED – BRAKES ELECTRICALLY RELEASED FOR TOWING |
| 2592-5 | MODEL CHANGED – HYDRAULICS SUSPENDED – CYCLE EMS |
| 25102-5 | DRIVE PREVENTED – BRAKES NOT RELEASING |
| 25112-5 | ELEV ANGLE SENSOR FAULTY – NOT MOUNTED |
| 25122-5 | ELEV ANGLE SENSOR NOT DETECTING CHANGE |
| 3113-1 | OPEN CIRCUIT LINE CONTACTOR |
| 3123-1 | CONTACTOR DRIVER PERMANENTLY OFF |
| 3143-1 | AUXILIARY RELAY – OPEN CIRCUIT |
| 3213-2 | LINE CONTACTOR MISWIRED ON OR WELDED |
| 3223-2 | CONTACTOR DRIVER PERMANENTLY ON |
| 3263-2 | AUXILIARY RELAY SHORT TO BATTERY |
| 3313-3 | BRAKE SHORT TO BATTERY |
| 3323-3 | BRAKE OPEN CIRCUIT |
| 3333-3 | LIFT UP SHORT TO BATTERY |
| 3343-3 | LIFT UP OPEN CIRCUIT |
| 3353-3 | LIFT DN SHORT TO BATTERY |
| 3363-3 | LIFT DN OPEN CIRCUIT |
| 3373-3 | STEER LEFT SHORT TO BATTERY |
| 3383-3 | STEER LEFT OPEN CIRCUIT |
| 3393-3 | STEER RIGHT SHORT TO BATTERY |
| 33103-3 | STEER RIGHT OPEN CIRCUIT |
| 33113-3 | GROUND ALARM SHORT TO BATTERY |
| 33123-3 | LEFT BRAKE SHORT TO BATTERY |
| 33133-3 | RIGHT BRAKE SHORT TO BATTERY |
| 33143-3 | LEFT BRAKE OPEN CIRCUIT |
| 33153-3 | RIGHT BRAKE OPEN CIRCUIT |
| 332973-3 | LEFT BRAKE – SHORT TO GROUND |
| 332983-3 | STEER LEFT VALVE – SHORT TO GROUND |
| 332993-3 | LINE CONTACTOR COIL – SHORT TO BATTERY |
| 333023-3 | NEGATIVE SUPPLY – SHORT TO BATTERY |
| 333033-3 | NEGATIVE SUPPLY – SHORT TO GROUND |
| 333043-3 | RIGHT BRAKE – SHORT TO GROUND |
| 333053-3 | STEER RIGHT VALVE – SHORT TO GROUND |
| 333833-3 | BEACON LIGHT – OPEN CIRCUIT |
| 333843-3 | BEACON LIGHT – SHORT TO GROUND |
| 334063-3 | LIFT UP VALVE – SHORT TO GROUND |
| 334073-3 | LIFT DN VALVE – SHORT TO GROUND |
| 335623-3 | BEACON LIGHT – SHORT TO BATTERY |
| 4214-2 | POWER MODULE TOO HOT – PLEASE WAIT |
| 4224-2 | DRIVING AT CUTBACK – POWER MODULE CURRENT LIMIT |
| 4234-2 | LIFT UP AT CUTBACK – POWER MODULE CURRENT LIMIT |
| 4414-4 | BATTERY VOLTAGE TOO LOW – SYSTEM SHUTDOWN |
| 4424-4 | BATTERY VOLTAGE TOO HIGH – SYSTEM SHUTDOWN |
| 4434-4 | LSS BATTERY VOLTAGE TOO HIGH |
| 4444-4 | LSS BATTERY VOLTAGE TOO LOW |
| 4464-4 | LOGIC SUPPLY VOLTAGE OUT OF RANGE |
| 44214-4 | LOGIC SUPPLY VOLTAGE OUT OF RANGE |
| 44224-4 | LOGIC SUPPLY VOLTAGE OUT OF RANGE |
| 6616-6 | CANBUS FAILURE – POWER MODULE |
| 6626-6 | CANBUS FAILURE – PLATFORM MODULE |
| 6636-6 | CANBUS FAILURE – LOAD SENSING SYSTEM MODULE |
| 6646-6 | CANBUS FAILURE – ACCESSORY MODULE |
| 66356-6 | CANBUS FAILURE – CHASSIS TILT SENSOR |
| 6716-7 | ACCESSORY FAULT |
| 7717-7 | OPEN CIRCUIT DRIVE MOTOR WIRING |
| 7727-7 | STALLED TRACTION MOTOR OR POWER WIRING ERROR |
| 7737-7 | CAPACITOR BANK FAULT – CHECK POWER CIRCUITS |
| 7747-7 | SHORT CIRCUIT FIELD WIRING |
| 7757-7 | OPEN CIRCUIT FIELD WIRING |
| 7767-7 | STALLED PUMP MOTOR OR POWER WIRING ERROR |
| 7777-7 | OPEN CIRCUIT PUMP MOTOR WIRING |
| 7787-7 | TRACTION T HIGH – CHECK POWER CIRCUITS |
| 7797-7 | TRACTION T LOW – CHECK POWER CIRCUITS |
| 77107-7 | PUMP P HIGH – CHECK POWER CIRCUITS |
| 77117-7 | PUMP P LOW – CHECK POWER CIRCUITS |
| 77417-7 | ARMATURE BRAKING CURRENT TOO HIGH |
| 77427-7 | FIELD VOLTAGE IMPROPER |
| 8118-1 | TILT SENSOR NOT CALIBRATED |
| 8128-1 | NO DATA FROM TILT SENSOR – NOT CONNECTED OR FAULTY |
| 8218-2 | LSS CELL #1 ERROR |
| 8228-2 | LSS CELL #2 ERROR |
| 8238-2 | LSS CELL #3 ERROR |
| 8248-2 | LSS CELL #4 ERROR |
| 8258-2 | LSS HAS NOT BEEN CALIBRATED |
| 9919-9 | LSS WATCHDOG RESET |
| 9929-9 | LSS EEPROM ERROR |
| 9939-9 | LSS INTERNAL ERROR – PIN EXCITATION |
| 9949-9 | LSS INTERNAL ERROR – DRDY MISSING FROM A/D |
| 9959-9 | POWER MODULE FAILURE – PERSONALITY RANGE ERROR |
| 9969-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 9979-9 | POWER MODULE FAILURE – CHECK POWER CIRCUITS OR MOSFET SHORT CIRCUIT |
| 9989-9 | EEPROM FAILURE – CHECK ALL SETTINGS |
| 9999-9 | FUNCTION LOCKED OUT – POWER MODULE SOFTWARE VERSION IMPROPER |
| 99109-9 | FUNCTION LOCKED OUT – PLATFORM MODULE SOFTWARE VERSION IMPROPER |
| 99119-9 | FUNCTION LOCKED OUT – LSS MODULE SOFTWARE VERSION IMPROPER |
| 99129-9 | POWER MODULE FAILURE – SYSTEM MONITOR |
| 99179-9 | HIGH RESOLUTION ANALOG TO DIGITAL FAILURE – INTERRUPT LOST |
| 99249-9 | FUNCTIONS LOCKED OUT – MACHINE NOT CONFIGURED |
| 99509-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99519-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99529-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99539-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99549-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99559-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99569-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99579-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99589-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99609-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99629-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99639-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99649-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99699-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99709-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99719-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 991439-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 991449-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 991459-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 991469-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 991479-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 991489-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 991499-9 | POWER MODULE FAILURE – INTERNAL ERROR |
Source: 1930ES, 2032ES, 2632ES, 2646ES, 3246ES Service & Maintenance Manual (PVC 2004), Section 6 – Diagnostic Trouble Codes (DTC check tables), no. 31217119 (2021-04-26). Codes and their meaning can vary with the serial number: always check your machine's manual. PDF JLG 1930ES manuals
Code keeps coming back, or the machine will not work?
Request service7.8 m working height, with the platform at 5.8 m (current ES1932 values).
At 0.81 m wide and 1.63 m high with rails folded, it fits through doors and openings wider than 0.81 m. The old 1930ES was 0.76 m.
230 kg: 2 people indoors or 1 person outdoors.
1,565 kg in the European (CE) version of the ES1932.
The ES1932 succeeds the 1930ES: the same 8 m class, 0.81 m wide instead of 0.76 m, with 7.8 m working height. 1930ES manuals and parts remain available.
Four 6 V 213 Ah AGM batteries (24 V), with a 27 A automatic charger (current ES1932).
The price is on request: it depends on the configuration (options, tyres, accessories) and delivery. Ask Trapézio de Prismas, the official JLG dealer in Portugal, for a quote.
The JLG 1930ES operation, service and parts manuals are in our JLG manuals library, by serial number. You can also request genuine parts from the same page.
Scissor lifts
Narrow (0.81 m) electric scissor lift with 10 m working height, for doorways and tight aisles.
Scissor lifts
Electric scissor lift with 10 m working height, 545 kg capacity and a wide 1.17 m deck.
Scissor lifts
Electric scissor lift with 12 m working height and a large deck.
Get in touch. You will get a fast answer from people who know the machines.