Articulating boom lifts
JLG E300AJP
Narrow (1.22 m) 11 m electric articulating boom lift with JibPLUS® jib, for indoors and tight aisles.
- Working height
- 10.97 m
- Horizontal outreach
- 6.12 m

Electric articulating boom lift · 16 m
Electric articulating boom lift, quiet and emission-free, for indoors and finished floors.
Official JLG dealer in Portugal · sales, parts and technical service
The JLG E450AJ is the electric version of the 16 m articulating boom: 15.72 m working height, 7.24 m horizontal outreach and 230 kg capacity, with zero emissions and low noise.
At 1.75 m wide, on non-marking tyres, with a 48 V AGM battery system, it works inside factories, warehouses, shopping centres and halls on finished floors. AC drive motors and a 0.61 m inside turning radius make it easy to manoeuvre between aisles and columns.
The 1.24 m jib with 144° articulation and the 360° zero-tailswing turntable give the same positioning freedom as the diesel 450AJ, for work over machinery, racking or ductwork.
Values from the manufacturer's European (CE) spec sheet. They can vary with the configuration and options.
The main specifications of the JLG E450AJ next to similar models.
| Specification | JLG E450AJ | JLG 450AJ | JLG Toucan 10E | JLG E300AJP |
|---|---|---|---|---|
| Working height | 15.72 m | 15.77 m | 10.10 m | 10.97 m |
| Horizontal outreach | 7.24 m | 7.62 m | — | 6.12 m |
| Platform capacity | 230 kg | 250 kg | 200 kg (2 persons) | 230 kg |
| Machine weight | 6,670 kg | 6,495 kg | 2,980 kg | 7,100 kg |
| Power | Electric, 48 V | Diesel, Deutz 36 kW | Electric, 24 V | Electric, 48 V |
Transport: 6,670 kg and 6.45 × 1.75 × 2.01 m stowed: it travels on a plant lorry or machine trailer.
Where it works: designed for indoors and firm floors, with non-marking tyres and zero emissions. Check ground pressure (up to 5.3 kg/cm²) on slabs and raised floors. Gradeability up to 30%.
Batteries: eight 6 V 370 Ah batteries (48 V) with a 20 A automatic charger, for a shift of work with overnight charging.
Operator: The operator must be properly trained to use mobile elevating work platforms (MEWPs): the employer is required to ensure this (Decree-Law 50/2005). The IPAF/PAL card is the most widely recognised training.
Inspections: Like any work equipment that lifts people, it needs mandatory periodic inspections (DL 50/2005), in addition to the manufacturer's preventive maintenance.
The price of a new JLG E450AJ is on request: it depends on the configuration (options, tyres, power, accessories), lead time and delivery location. Tell us what the machine is for and we will send a quote.
Search the code the machine shows to see what it means.
Faults are logged while the key switch is in RUN and read with the JLG Analyzer (connected at the platform box or the power module). The system distress light flashes a two-digit flash code (e.g. 2-1 = footswitch/EMS). The Delta-Q battery charger shows its faults by flashing a code on its red LED (E-0-0-1, …).
302 codes
| Code | Meaning |
|---|---|
| 0010-0 | EVERYTHING OK |
| 0020-0 | GROUND MODE OK |
| 0080-0 | FUNCTIONS LOCKED OUT – SYSTEM POWERED DOWN |
| 00100-0 | RUNNING AT CUTBACK – OUT OF TRANSPORT POSITION |
| 00110-0 | FSW OPEN |
| 00120-0 | RUNNING AT CREEP – CREEP SWITCH OPEN |
| 00130-0 | RUNNING AT CREEP – TILTED AND ABOVE ELEVATION |
| 00330-0 | TRACTION MOTOR AT CURRENT LIMIT |
| 00360-0 | FUNCTION PREVENTED – FUNCTION SELECTED BEFORE GROUND ENABLE |
| 00390-0 | SKYGUARD ACTIVE – FUNCTIONS CUTOUT |
| 00470-0 | DRIVING IN CREEP – STEEP DESCENT |
| 00480-0 | BATTERY CHARGE LOW |
| 00460-0 | TORQUE CUTBACK – EXCESSIVE TILT |
| 2112-1 | POWER CYCLE |
| 2122-1 | KEYSWITCH FAULTY |
| 2132-1 | FSW FAULTY |
| 2212-2 | FUNCTION PROBLEM – HORN PERMANENTLY SELECTED |
| 2242-2 | FUNCTION PROBLEM – STEER LEFT PERMANENTLY SELECTED |
| 2252-2 | FUNCTION PROBLEM – STEER RIGHT PERMANENTLY SELECTED |
| 2272-2 | STEER SWITCHES FAULTY |
| 22112-2 | FSW INTERLOCK TRIPPED |
| 22122-2 | DRIVE LOCKED – JOYSTICK MOVED BEFORE FOOTSWITCH |
| 22132-2 | STEER LOCKED – SELECTED BEFORE FOOTSWITCH |
| 22162-2 | D/S JOY. OUT OF RANGE HIGH |
| 22172-2 | D/S JOY. CENTER TAP BAD |
| 22192-2 | L/S JOY. OUT OF RANGE HIGH |
| 22202-2 | L/S JOY. CENTER TAP BAD |
| 22212-2 | LIFT/SWING LOCKED – JOYSTICK MOVED BEFORE FOOTSWITCH |
| 22222-2 | WAITING FOR FSW TO BE OPEN |
| 22232-2 | FUNCTION SWITCHES LOCKED – SELECTED BEFORE ENABLE |
| 22452-2 | FUNCTION PROBLEM – JIB SWING LEFT PERMANENTLY SELECTED |
| 22462-2 | FUNCTION PROBLEM – JIB SWING RIGHT PERMANENTLY SELECTED |
| 22472-2 | FUNCTION PROBLEM – PLATFORM ROTATE LEFT PERMANENTLY SELECTED |
| 22482-2 | FUNCTION PROBLEM – PLATFORM ROTATE RIGHT PERMANENTLY SELECTED |
| 22492-2 | FUNCTION PROBLEM – JIB LIFT UP PERMANENTLY SELECTED |
| 22502-2 | FUNCTION PROBLEM – JIB LIFT DOWN PERMANENTLY SELECTED |
| 22512-2 | FUNCTION PROBLEM – TELESCOPE IN PERMANENTLY SELECTED |
| 22522-2 | FUNCTION PROBLEM – TELESCOPE OUT PERMANENTLY SELECTED |
| 22572-2 | FUNCTION PROBLEM – TOWER LIFT UP PERMANENTLY SELECTED |
| 22582-2 | FUNCTION PROBLEM – TOWER LIFT DOWN PERMANENTLY SELECTED |
| 22622-2 | FUNCTION PROBLEM – PLATFORM LEVEL UP PERMANENTLY SELECTED |
| 22632-2 | FUNCTION PROBLEM – PLATFORM LEVEL DOWN PERMANENTLY SELECTED |
| 22642-2 | FUNCTION PROBLEM – DOS OVERRIDE PERMANENTLY SELECTED |
| 22862-2 | FUNCTION PROBLEM – SOFT TOUCH/SKYGUARD OVERRIDE PERMANENTLY SELECTED |
| 2342-3 | FUNCTION SWITCHES FAULTY – CHECK DIAGNOSTICS/BOOM |
| 23102-3 | FUNCTION PROBLEM – GROUND ENABLE PERMANENTLY SELECTED |
| 23702-3 | FUNCTION PROBLEM – JIB LIFT UP PERMANENTLY SELECTED |
| 23712-3 | FUNCTION PROBLEM – JIB LIFT DOWN PERMANENTLY SELECTED |
| 23722-3 | FUNCTION PROBLEM – SWING LEFT PERMANENTLY SELECTED |
| 23732-3 | FUNCTION PROBLEM – SWING RIGHT PERMANENTLY SELECTED |
| 231052-3 | FUNCTION PROBLEM – TOWER LIFT UP PERMANENTLY SELECTED |
| 231062-3 | FUNCTION PROBLEM – TOWER LIFT DOWN PERMANENTLY SELECTED |
| 231072-3 | FUNCTION PROBLEM – LIFT UP PERMANENTLY SELECTED |
| 231082-3 | FUNCTION PROBLEM – LIFT DOWN PERMANENTLY SELECTED |
| 231092-3 | FUNCTION PROBLEM – TELESCOPE IN PERMANENTLY SELECTED |
| 231102-3 | FUNCTION PROBLEM – TELESCOPE OUT PERMANENTLY SELECTED |
| 231112-3 | FUNCTION PROBLEM – PLATFORM LEVEL UP PERMANENTLY SELECTED |
| 231122-3 | FUNCTION PROBLEM – PLATFORM LEVEL DOWN PERMANENTLY SELECTED |
| 231132-3 | FUNCTION PROBLEM – PLATFORM ROTATE LEFT PERMANENTLY SELECTED |
| 231142-3 | FUNCTION PROBLEM – PLATFORM ROTATE RIGHT PERMANENTLY SELECTED |
| 231632-3 | FUNCTION PROBLEM – MSSO PERMANENTLY SELECTED |
| 231712-3 | FUNCTION PROBLEM – JIB SWING LEFT PERMANENTLY SELECTED |
| 231722-3 | FUNCTION PROBLEM – JIB SWING RIGHT PERMANENTLY SELECTED |
| 2412-4 | AMBIENT TEMPERATURE SENSOR – OUT OF RANGE LOW |
| 2422-4 | AMBIENT TEMPERATURE SENSOR – OUT OF RANGE HIGH |
| 2532-5 | DRIVE PREVENTED – CHARGER CONNECTED |
| 2592-5 | MODEL CHANGED – HYDRAULICS SUSPENDED – CYCLE EMS |
| 25142-5 | BOOM PREVENTED – DRIVE SELECTED |
| 25162-5 | DRIVE PREVENTED – ABOVE ELEVATION |
| 25182-5 | DRIVE PREVENTED – BOOM SELECTED |
| 25382-5 | FUNCTION PREVENTED – CHARGER CONNECTED |
| 25482-5 | SYSTEM TEST MODE ACTIVE |
| 25492-5 | DRIVE & BOOM PREVENTED – SOFT TOUCH ACTIVE |
| 25632-5 | SKYGUARD SWITCH – DISAGREEMENT |
| 25642-5 | DRIVE PREVENTED – LEFT BRAKE NOT RELEASING |
| 25652-5 | DRIVE PREVENTED – RIGHT BRAKE NOT RELEASING |
| 25682-5 | TEMPERATURE CUTOUT ACTIVE – AMBIENT TEMPERATURE TOO LOW |
| 25762-5 | PLATFORM LEVEL PREVENTED – ABOVE ELEVATION |
| 25782-5 | FUNCTION PREVENTED – TILTED & ABOVE ELEVATION |
| 25792-5 | DRIVE PREVENTED – EXCESSIVE GRADE |
| 31113-1 | MAIN CONTACTOR DRIVER – PERMANENTLY OFF |
| 31123-1 | MAIN CONTACTOR – OPEN CIRCUIT |
| 32123-2 | MAIN CONTACTOR – WELDED OR MISWIRED |
| 32133-2 | MAIN CONTACTOR DRIVER – PERMANENTLY ON |
| 3343-3 | LIFT UP VALVE – OPEN CIRCUIT |
| 3363-3 | LIFT DOWN VALVE – OPEN CIRCUIT |
| 3373-3 | STEER LEFT VALVE – SHORT TO BATTERY |
| 3383-3 | STEER LEFT VALVE – OPEN CIRCUIT |
| 3393-3 | STEER RIGHT VALVE – SHORT TO BATTERY |
| 33103-3 | STEER RIGHT VALVE – OPEN CIRCUIT |
| 33113-3 | GROUND ALARM – SHORT TO BATTERY |
| 33713-3 | GROUND ALARM – SHORT TO GROUND |
| 33763-3 | HEAD TAIL LIGHT – SHORT TO GROUND |
| 33773-3 | HEAD TAIL LIGHT – OPEN CIRCUIT |
| 33783-3 | HEAD TAIL LIGHT – SHORT TO BATTERY |
| 33823-3 | PLATFORM LEVEL UP VALVE – SHORT TO GROUND |
| 33833-3 | PLATFORM LEVEL UP VALVE – OPEN CIRCUIT |
| 33843-3 | PLATFORM LEVEL UP VALVE – SHORT TO BATTERY |
| 33883-3 | PLATFORM LEVEL DOWN VALVE – SHORT TO GROUND |
| 33893-3 | PLATFORM LEVEL DOWN VALVE – OPEN CIRCUIT |
| 33903-3 | PLATFORM LEVEL DOWN VALVE – SHORT TO BATTERY |
| 33943-3 | PLATFORM ROTATE LEFT VALVE – SHORT TO GROUND |
| 33953-3 | PLATFORM ROTATE LEFT VALVE – OPEN CIRCUIT |
| 33963-3 | PLATFORM ROTATE LEFT VALVE – SHORT TO BATTERY |
| 33973-3 | PLATFORM ROTATE RIGHT VALVE – SHORT TO GROUND |
| 33983-3 | PLATFORM ROTATE RIGHT VALVE – OPEN CIRCUIT |
| 33993-3 | PLATFORM ROTATE RIGHT VALVE – SHORT TO BATTERY |
| 331003-3 | JIB LIFT UP VALVE – SHORT TO GROUND |
| 331013-3 | JIB LIFT UP VALVE – OPEN CIRCUIT |
| 331023-3 | JIB LIFT UP VALVE – SHORT TO BATTERY |
| 331033-3 | JIB LIFT DOWN VALVE – SHORT TO GROUND |
| 331043-3 | JIB LIFT DOWN VALVE – OPEN CIRCUIT |
| 331053-3 | JIB LIFT DOWN VALVE – SHORT TO BATTERY |
| 331063-3 | TOWER LIFT UP VALVE – SHORT TO GROUND |
| 331073-3 | TOWER LIFT UP VALVE – OPEN CIRCUIT |
| 331083-3 | TOWER LIFT UP VALVE – SHORT TO BATTERY |
| 331093-3 | TOWER LIFT DOWN VALVE – SHORT TO GROUND |
| 331103-3 | TOWER LIFT DOWN VALVE – OPEN CIRCUIT |
| 331113-3 | TOWER LIFT DOWN VALVE – SHORT TO BATTERY |
| 331183-3 | SWING RIGHT VALVE – SHORT TO GROUND |
| 331193-3 | SWING RIGHT VALVE – OPEN CIRCUIT |
| 331203-3 | TELESCOPE IN VALVE – SHORT TO BATTERY |
| 331223-3 | SWING LEFT VALVE – SHORT TO GROUND |
| 331233-3 | TELESCOPE OUT VALVE – SHORT TO BATTERY |
| 331753-3 | JIB ROTATE LEFT VALVE – OPEN CIRCUIT |
| 331763-3 | JIB ROTATE LEFT VALVE – SHORT TO BATTERY |
| 331773-3 | JIB ROTATE LEFT VALVE – SHORT TO GROUND |
| 331783-3 | JIB ROTATE RIGHT VALVE – OPEN CIRCUIT |
| 331793-3 | JIB ROTATE RIGHT VALVE – SHORT TO BATTERY |
| 331803-3 | JIB ROTATE RIGHT VALVE – SHORT TO GROUND |
| 331823-3 | LIFT VALVES – SHORT TO BATTERY |
| 331863-3 | TELESCOPE OUT VALVE – OPEN CIRCUIT |
| 331883-3 | TELESCOPE OUT VALVE – SHORT TO GROUND |
| 331893-3 | TELESCOPE IN VALVE – OPEN CIRCUIT |
| 331903-3 | TELESCOPE IN VALVE – SHORT TO GROUND |
| 332953-3 | SWING LEFT VALVE – OPEN CIRCUIT |
| 332983-3 | STEER LEFT – SHORT TO GROUND |
| 333053-3 | STEER RIGHT – SHORT TO GROUND |
| 333143-3 | FLOW CONTROL VALVE – OPEN CIRCUIT |
| 333153-3 | FLOW CONTROL VALVE – SHORT TO BATTERY |
| 333163-3 | FLOW CONTROL VALVE – SHORT TO GROUND |
| 334063-3 | LIFT UP VALVE – SHORT TO GROUND |
| 334073-3 | LIFT DOWN VALVE – SHORT TO GROUND |
| 334123-3 | SWING VALVES – SHORT TO BATTERY |
| 334253-3 | TOWER LIFT VALVES – SHORT TO BATTERY |
| 334793-3 | VOTING RELAY – SHORT TO BATTERY |
| 334803-3 | VOTING RELAY – SHORT TO GROUND |
| 335493-3 | VOTING RELAY – OPEN CIRCUIT |
| 335783-3 | STEER PRIORITY BYPASS VALVE – OPEN CIRCUIT |
| 335793-3 | STEER PRIORITY BYPASS VALVE – SHORT TO GROUND |
| 335803-3 | STEER PRIORITY BYPASS VALVE – SHORT TO BATTERY |
| 336243-3 | SWING BYPASS VALVE – SHORT TO GROUND |
| 336253-3 | SWING BYPASS VALVE – SHORT TO BATTERY |
| 336263-3 | SWING BYPASS VALVE – OPEN CIRCUIT |
| 336273-3 | LIFT BYPASS VALVE – SHORT TO GROUND |
| 336283-3 | LIFT BYPASS VALVE – SHORT TO BATTERY |
| 336293-3 | LIFT BYPASS VALVE – OPEN CIRCUIT |
| 42194-2 | REAR LEFT MODULE TEMPERATURE – OUT OF RANGE |
| 42204-2 | REAR RIGHT MODULE TEMPERATURE – OUT OF RANGE |
| 42234-2 | REAR LEFT MODULE TOO HOT – PLEASE WAIT |
| 42244-2 | REAR RIGHT MODULE TOO HOT – PLEASE WAIT |
| 42284-2 | REAR LEFT MOTOR TEMPERATURE – OUT OF RANGE |
| 42294-2 | REAR RIGHT MOTOR TEMPERATURE – OUT OF RANGE |
| 42324-2 | REAR LEFT MOTOR TOO HOT – PLEASE WAIT |
| 42334-2 | REAR RIGHT MOTOR TOO HOT – PLEASE WAIT |
| 4414-4 | BATTERY VOLTAGE TOO LOW – SYSTEM SHUTDOWN |
| 4424-4 | BATTERY VOLTAGE TOO HIGH – SYSTEM SHUTDOWN |
| 4434-4 | LSS BATTERY VOLTAGE TOO HIGH |
| 4444-4 | LSS BATTERY VOLTAGE TOO LOW |
| 44204-4 | BATTERY DEEPLY DISCHARGED |
| 44304-4 | BATTERY VOLTAGE TOO LOW |
| 44634-4 | REAR LEFT MODULE – VOLTAGE OUT OF RANGE |
| 44644-4 | REAR RIGHT MODULE – VOLTAGE OUT OF RANGE |
| 46924-6 | REAR LEFT BRAKE – SHORT TO GROUND OR OPEN CIRCUIT |
| 46934-6 | REAR RIGHT BRAKE – SHORT TO GROUND OR OPEN CIRCUIT |
| 461004-6 | REAR LEFT BRAKE RETURN – SHORT TO BATTERY |
| 461304-6 | MAIN CONTACTOR/REAR RIGHT BRAKE RETURN – SHORT TO BATTERY |
| 461044-6 | REAR LEFT SPEED SENSOR – NOT RESPONDING PROPERLY |
| 461054-6 | REAR RIGHT SPEED SENSOR – NOT RESPONDING PROPERLY |
| 461084-6 | REAR LEFT SPEED SENSOR – RPM HIGH |
| 461094-6 | REAR RIGHT SPEED SENSOR – RPM HIGH |
| 461364-6 | REAR LEFT BRAKE SUPPLY VOLTAGE – OUT OF RANGE LOW |
| 461374-6 | REAR RIGHT BRAKE SUPPLY VOLTAGE – OUT OF RANGE LOW |
| 6626-6 | CANBUS FAILURE – PLATFORM MODULE |
| 6636-6 | CANBUS FAILURE – LOAD SENSING SYSTEM MODULE |
| 66136-6 | CANBUS FAILURE – EXCESSIVE CANBUS ERRORS |
| 66356-6 | CANBUS FAILURE – CHASSIS TILT SENSOR |
| 66546-6 | CANBUS FAILURE – REAR LEFT MODULE |
| 66556-6 | CANBUS FAILURE – REAR RIGHT MODULE |
| 66576-6 | CANBUS FAILURE – TEMPERATURE SENSOR |
| 77257-7 | PUMP MOTOR – NOT RESPONDING |
| 77307-7 | PUMP MOTOR OUTPUT – OUT OF RANGE HIGH |
| 77317-7 | PUMP MOTOR OUTPUT – OUT OF RANGE LOW |
| 77377-7 | PUMP MOTOR OVERLOADED |
| 77537-7 | REAR LEFT MOTOR STALLED |
| 77547-7 | REAR RIGHT MOTOR STALLED |
| 77577-7 | REAR LEFT MOTOR OUTPUT – OUT OF RANGE HIGH |
| 77587-7 | REAR RIGHT MOTOR OUTPUT – OUT OF RANGE HIGH |
| 77617-7 | REAR LEFT MOTOR OUTPUT – OUT OF RANGE LOW |
| 77627-7 | REAR RIGHT MOTOR OUTPUT – OUT OF RANGE LOW |
| 77657-7 | REAR LEFT MOTOR – FEEDBACK FAILURE |
| 77667-7 | REAR RIGHT MOTOR – FEEDBACK FAILURE |
| 77697-7 | REAR LEFT MOTOR – ROTATION OPPOSITE CONTROL |
| 77707-7 | REAR RIGHT MOTOR – ROTATION OPPOSITE CONTROL |
| 77737-7 | REAR LEFT MOTOR – OPEN CIRCUIT |
| 77747-7 | REAR RIGHT MOTOR – OPEN CIRCUIT |
| 8138-1 | CHASSIS TILT SENSOR NOT CALIBRATED |
| 8148-1 | CHASSIS TILT SENSOR OUT OF RANGE |
| 8188-1 | TILT SENSOR STAGNANT |
| 8218-2 | LSS CELL #1 ERROR |
| 8228-2 | LSS CELL #2 ERROR |
| 8238-2 | LSS CELL #3 ERROR |
| 8248-2 | LSS CELL #4 ERROR |
| 8258-2 | LSS HAS NOT BEEN CALIBRATED |
| 8268-2 | RUNNING AT CREEP – PLATFORM OVERLOADED |
| 8298-2 | FUNCTIONS CUTOUT – PLATFORM OVERLOADED |
| 82118-2 | LSS READING UNDER WEIGHT |
| 86648-6 | STEER SENSOR – OUT OF RANGE HIGH |
| 86658-6 | STEER SENSOR – OUT OF RANGE LOW |
| 86668-6 | STEER SENSOR – DECOUPLED |
| 86678-6 | STEER SENSOR – NOT RESPONDING |
| 86688-6 | STEER SENSOR – NOT CALIBRATED |
| 8738-7 | MACHINE SAFETY SYSTEM OVERRIDE OCCURRED |
| 9919-9 | LSS WATCHDOG RESET |
| 9929-9 | LSS EEPROM ERROR |
| 9939-9 | LSS INTERNAL ERROR – PIN EXCITATION |
| 9949-9 | LSS INTERNAL ERROR – DRDY MISSING FROM A/D |
| 9989-9 | EEPROM FAILURE – CHECK ALL SETTINGS |
| 99109-9 | FUNCTIONS LOCKED OUT – PLATFORM MODULE SOFTWARE VERSION IMPROPER |
| 99119-9 | FUNCTIONS LOCKED OUT – LSS MODULE SOFTWARE VERSION IMPROPER |
| 99199-9 | GROUND SENSOR REF VOLTAGE OUT OF RANGE |
| 99209-9 | PLATFORM SENSOR REF VOLTAGE OUT OF RANGE |
| 99219-9 | GROUND MODULE FAILURE – HIGH SIDE DRIVER CUTOUT FAULTY |
| 99229-9 | PLATFORM MODULE FAILURE – HWFS CODE 1 |
| 99249-9 | FUNCTIONS LOCKED OUT – MACHINE NOT CONFIGURED |
| 99279-9 | GROUND MODULE CONSTANT DATA UPDATE REQUIRED |
| 99449-9 | CURRENT FEEDBACK GAINS OUT OF RANGE |
| 99459-9 | CURRENT FEEDBACK CALIBRATION CHECKSUM INCORRECT |
| 99499-9 | MACHINE CONFIGURATION OUT OF RANGE – CHECK ALL SETTINGS |
| 99779-9 | LSS CORRUPT EEPROM |
| 99799-9 | FUNCTIONS LOCKED OUT – GROUND MODULE SOFTWARE VERSION IMPROPER |
| 99869-9 | GROUND MODULE VLOW FET FAILURE |
| 991679-9 | PUMP COMMAND ERROR |
| 992349-9 | REAR LEFT MODULE – EEPROM FAILURE |
| 992359-9 | REAR LEFT MODULE – PROTECTION FAILURE |
| 992369-9 | REAR LEFT MODULE – CHECK POWER CIRCUITS OR MOSFET SHORT CIRCUIT |
| 992379-9 | REAR LEFT MODULE – WATCHDOG RESET |
| 992389-9 | REAR LEFT MODULE – WATCHDOG2 RESET |
| 992399-9 | REAR LEFT MODULE – RAM FAILURE |
| 992409-9 | REAR LEFT MODULE – INTERNAL ERROR |
| 992419-9 | REAR LEFT MODULE – INTERNAL ERROR |
| 992429-9 | REAR LEFT MODULE – INTERNAL ERROR |
| 992439-9 | REAR LEFT MODULE – INTERNAL ERROR |
| 992449-9 | REAR LEFT MODULE – INTERNAL ERROR |
| 992459-9 | REAR LEFT MODULE – INTERNAL ERROR |
| 992469-9 | REAR LEFT MODULE – CAPACITOR BANK FAULT |
| 992479-9 | REAR LEFT MODULE – A/D FAILURE |
| 992489-9 | REAR RIGHT MODULE – EEPROM FAILURE |
| 992499-9 | REAR RIGHT MODULE – PROTECTION FAILURE |
| 992509-9 | REAR RIGHT MODULE – CHECK POWER CIRCUITS OR MOSFET SHORT CIRCUIT |
| 992519-9 | REAR RIGHT MODULE – WATCHDOG RESET |
| 992529-9 | REAR RIGHT MODULE – WATCHDOG2 RESET |
| 992539-9 | REAR RIGHT MODULE – RAM FAILURE |
| 992549-9 | REAR RIGHT MODULE – INTERNAL ERROR |
| 992559-9 | REAR RIGHT MODULE – INTERNAL ERROR |
| 992569-9 | REAR RIGHT MODULE – INTERNAL ERROR |
| 992579-9 | REAR RIGHT MODULE – INTERNAL ERROR |
| 992589-9 | REAR RIGHT MODULE – INTERNAL ERROR |
| 992599-9 | REAR RIGHT MODULE – INTERNAL ERROR |
| 992609-9 | REAR RIGHT MODULE – CAPACITOR BANK FAULT |
| 992619-9 | REAR RIGHT MODULE – A/D FAILURE |
| 992649-9 | REAR LEFT MODULE – CURRENT MEASUREMENT ERROR |
| 992659-9 | REAR RIGHT MODULE – CURRENT MEASUREMENT ERROR |
| 992709-9 | REAR RIGHT MODULE – DRIVE COMMAND ERROR |
| 992699-9 | REAR LEFT MODULE – DRIVE COMMAND ERROR |
| 992739-9 | FUNCTIONS LOCKED OUT – REAR LEFT MODULE SOFTWARE VERSION IMPROPER |
| 992749-9 | FUNCTIONS LOCKED OUT – REAR RIGHT MODULE SOFTWARE VERSION IMPROPER |
| 992819-9 | FUNCTIONS LOCKED OUT – IMPROPER MOTOR PARAMETERS |
| 6826-8 | FUNCTIONS IN CREEP – CONNECTIVITY INTERLOCK |
| 6836-8 | FUNCTIONS IN CREEP AND RESTRICTED TO TRANSPORT – CONNECTIVITY INTERLOCK |
| 6846-8 | FUNCTIONS LOCKED OUT – CONNECTIVITY INTERLOCK |
| 6856-8 | ALL FUNCTIONS LOCKED OUT – CONNECTIVITY INTERLOCK |
| 6866-8 | ENGINE START PREVENTED – CONNECTIVITY INTERLOCK |
| 661116-6 | CANBUS FAILURE – CONNECTIVITY MODULE |
| E-0-0-1 | Battery voltage high |
| E-0-0-2 | Battery voltage low |
| E-0-0-3 | Charge timeout caused by battery pack not reaching required voltage within safe time limit. |
| E-0-0-4 | Battery could not meet minimum voltage |
| E-0-0-7 | Battery amp hour limit exceeded |
| E-0-0-8 | Battery temperature is out of range |
| E-0-1-2 | Reverse polarity error |
| E-0-1-6 | USB operation failed |
| E-0-1-8 | USB operation failed |
| E-0-2-6 | USB operation failed |
| E-0-2-3 | High AC voltage error (>270 VAC) |
| E-0-2-4 | Charger failed to initialize |
| E-0-2-5 | Low AC voltage oscillation error |
| F-0-0-1 | Internal charger fault |
| F-0-0-2 | Internal charger fault |
| F-0-0-3 | Internal charger fault |
| F-0-0-4 | Internal charger fault |
| F-0-0-6 | Internal charger fault |
Source: E450AJ Service & Maintenance Manual (PVC 2607), Table 21 – Diagnostic Trouble Codes; Table 19 – Flash Codes; Table 3 – Battery Charger Fault Codes (Delta-Q), no. 3122577300 (2026-09-30). Codes and their meaning can vary with the serial number: always check your machine's manual. PDF JLG E450AJ manuals
Code keeps coming back, or the machine will not work?
Request service15.72 m working height (platform at 13.72 m) and 7.24 m horizontal outreach.
Yes, that is what it is for: it is electric, emission-free, quiet and has non-marking tyres. At 1.75 m wide it fits through warehouse doors and aisles.
6,670 kg (CE version). Stowed it measures 6.45 × 1.75 × 2.01 m.
Capacity is 230 kg, which normally corresponds to 2 people with tools. Always check the machine's capacity plate.
Eight 6 V 370 Ah AGM batteries (48 V system) with a 20 A automatic charger. Higher-capacity battery options are available.
The price is on request: it depends on the configuration (options, tyres, accessories) and delivery. Ask Trapézio de Prismas, the official JLG dealer in Portugal, for a quote.
The JLG E450AJ operation, service and parts manuals are in our JLG manuals library, by serial number. You can also request genuine parts from the same page.
Articulating boom lifts
Narrow (1.22 m) 11 m electric articulating boom lift with JibPLUS® jib, for indoors and tight aisles.
Articulating boom lifts
Diesel articulating boom lift with jib, for up-and-over reach on site.
Articulating boom lifts
Diesel articulating boom lift with 18 m working height, jib, 250 kg capacity and zero tailswing.
Get in touch. You will get a fast answer from people who know the machines.