Articulating boom lifts
JLG E300AJP
Narrow (1.22 m) 11 m electric articulating boom lift with JibPLUS® jib, for indoors and tight aisles.
- Working height
- 10.97 m
- Horizontal outreach
- 6.12 m

Electric mast boom lift · 10 m
Electric vertical mast lift with jib, compact and agile for indoor work.
Also known as: T10E
Official JLG dealer in Portugal · sales, parts and technical service
The JLG Toucan 10E is an electric vertical mast lift with a jib: 10.10 m working height, 3.38 m working outreach and 200 kg (2 people), in a machine 0.99 m wide.
The 1.60 m jib with 126° articulation and the 345° turntable reach over racking, machinery or ducts with the base standing still, which a scissor lift cannot do. Tailswing is just 0.12 m.
Non-marking tyres, AC drive motors and zero emissions. It can work indoors and outdoors with 2 people (wind up to 12.5 m/s): warehouses, shops, factories and public buildings.
Values from the manufacturer's European (CE) spec sheet. They can vary with the configuration and options.
The main specifications of the JLG Toucan 10E next to similar models.
| Specification | JLG Toucan 10E | JLG E450AJ | JLG 1930ES |
|---|---|---|---|
| Working height | 10.10 m | 15.72 m | 7.8 m |
| Working outreach | 3.38 m (standard platform) | — | — |
| Platform capacity | 200 kg (2 persons) | 230 kg | 230 kg (2 persons indoor / 1 outdoor) |
| Machine weight | 2,980 kg | 6,670 kg | 1,565 kg |
| Power | Electric, 24 V | Electric, 48 V | Electric, 24 V |
Transport: 2,980 kg and 2.82 × 0.99 × 1.99 m stowed: trailer or lorry with ramps.
Where it works: indoors and outdoors, with 2 people and wind up to 12.5 m/s. Maximum ground pressure is high (21.5 kg/cm², small solid tyres): check the strength of raised floors. Gradeability 25%.
Batteries: AGM 24 V – 260 Ah with a 27 A charger.
Operator: The operator must be properly trained to use mobile elevating work platforms (MEWPs): the employer is required to ensure this (Decree-Law 50/2005). The IPAF/PAL card is the most widely recognised training.
Inspections: Like any work equipment that lifts people, it needs mandatory periodic inspections (DL 50/2005), in addition to the manufacturer's preventive maintenance.
The price of a new JLG Toucan 10E is on request: it depends on the configuration (options, tyres, power, accessories), lead time and delivery location. Tell us what the machine is for and we will send a quote.
Search the code the machine shows to see what it means.
DTCs are read from the analyzer and are also displayed on the Multi Display Indicator (MDI, ground console) and on the face of the platform console. DTCs are sorted in groups by the first two digits, which are also the system distress lamp flash code. The manual says to refer problems to a qualified JLG mechanic.
201 codes
| Code | Meaning |
|---|---|
| 0010-0 | EVERYTHING OK |
| 0020-0 | GROUND MODE OK |
| 0080-0 | FUNCTIONS LOCKED OUT – SYSTEM POWERED DOWN |
| 00100-0 | RUNNING AT CUTBACK – OUT OF TRANSPORT POSITION |
| 00220-0 | DIFFERENT FUNCTION SELECTED & IGNORED |
| 00230-0 | FUNCTION SELECTED BUT TRIGGER SWITCH OPEN |
| 00270-0 | FUNCTION SELECTED BUT LIFT ENABLE SWITCH OPEN |
| 00280-0 | DRIVE PREVENTED – TILTED & ELEVATED |
| 00290-0 | RUNNING AT CREEP – MAX ELEVATION |
| 00350-0 | APU ACTIVE |
| 00360-0 | FUNCTION PREVENTED – FUNCTION SELECTED BEFORE GROUND ENABLE |
| 00390-0 | SKYGUARD ACTIVE – FUNCTIONS CUTOUT |
| 2112-1 | POWER CYCLE |
| 2122-1 | KEYSWITCH FAULTY |
| 2212-2 | FUNCTION PROBLEM – HORN PERMANENTLY SELECTED |
| 2242-2 | FUNCTION PROBLEM – STEER LEFT PERMANENTLY SELECTED |
| 2252-2 | FUNCTION PROBLEM – STEER RIGHT PERMANENTLY SELECTED |
| 2272-2 | STEER SWITCHES FAULTY |
| 2292-2 | FUNCTION PROBLEM – TRIGGER PERMANENTLY CLOSED |
| 22102-2 | TRIGGER CLOSED TOO LONG WHILE IN NEUTRAL |
| 22402-2 | LIFT ENABLE SWITCH PERMANENTLY SELECTED |
| 22412-2 | LIFT ENABLE SWITCH CLOSED TOO LONG WHILE IN NEUTRAL |
| 22422-2 | FUNCTION LOCKED OUT – MAST JOYSTICK NOT CENTERED |
| 22432-2 | FUNCTION LOCKED OUT – JIB JOYSTICK NOT CENTERED |
| 22492-2 | DRIVE & BOOM PREVENTED – SOFT TOUCH ACTIVE |
| 22642-2 | FUNCTION PROBLEM – DOS OVERRIDE PERMANENTLY SELECTED |
| 22742-2 | DRIVE/SWING JOYSTICK FAULTY – WIPER OUT OF RANGE |
| 22752-2 | FUNCTION LOCKED OUT – DRIVE/SWING JOYSTICK NOT CENTERED |
| 22772-2 | MAST JOYSTICK FAULTY – WIPER OUT OF RANGE |
| 22792-2 | JIB JOYSTICK FAULTY – WIPER OUT OF RANGE |
| 22862-2 | FUNCTION PROBLEM – SOFT TOUCH/SKYGUARD OVERRIDE PERMANENTLY SELECTED |
| 2332-3 | FUNCTION PROBLEM – BRAKE RELEASE PERMANENTLY SELECTED |
| 23102-3 | FUNCTION PROBLEM – GROUND ENABLE PERMANENTLY SELECTED |
| 23682-3 | FUNCTION PROBLEM – MAST LIFT UP PERMANENTLY SELECTED |
| 23692-3 | FUNCTION PROBLEM – MAST LIFT DOWN PERMANENTLY SELECTED |
| 23702-3 | FUNCTION PROBLEM – JIB LIFT UP PERMANENTLY SELECTED |
| 23712-3 | FUNCTION PROBLEM – JIB LIFT DOWN PERMANENTLY SELECTED |
| 23722-3 | FUNCTION PROBLEM – SWING LEFT PERMANENTLY SELECTED |
| 23732-3 | FUNCTION PROBLEM – SWING RIGHT PERMANENTLY SELECTED |
| 23742-3 | MAST SWITCH FAULTY |
| 23752-3 | JIB SWITCH FAULTY |
| 23762-3 | SWING SWITCH FAULTY |
| 23772-3 | CHAIN SLACK SWITCH DISAGREEMENT |
| 23782-3 | MAIN MAST LIMIT SWITCH – DECOUPLED |
| 23792-3 | MAIN MAST LIMIT SWITCH – NOT RESPONDING |
| 23802-3 | MAIN MAST LIMIT SWITCH – FAULTY |
| 23812-3 | MAST LIMIT SWITCH 2- FAULTY |
| 231622-3 | MSSO SWITCH FAULTY |
| 231632-3 | FUNCTION PROBLEM – MSSO PERMANENTLY SELECTED |
| 232532-3 | MACHINE SETUP WIRING – ERROR |
| 2412-4 | AMBIENT TEMPERATURE SENSOR – OUT OF RANGE LOW |
| 2422-4 | AMBIENT TEMPERATURE SENSOR – OUT OF RANGE HIGH |
| 2532-5 | DRIVE PREVENTED – CHARGER CONNECTED |
| 2592-5 | MODEL CHANGED – HYDRAULICS SUSPENDED – CYCLE EMS |
| 25162-5 | DRIVE PREVENTED – ABOVE ELEVATION |
| 25382-5 | FUNCTION PREVENTED – CHARGER CONNECTED |
| 25422-5 | FUNCTION PREVENTED – BRAKES ELECTRONICALLY RELEASED FOR TOWING |
| 25432-5 | FUNCTION PREVENTED – CHAIN SLACK DETECTED |
| 25482-5 | SYSTEM TEST MODE ACTIVE |
| 25632-5 | SKYGUARD SWITCH – DISAGREEMENT |
| 25682-5 | TEMPERATURE CUTOUT ACTIVE – AMBIENT TEMPERATURE TOO LOW |
| 251592-5 | FUNCTION PREVENTED – PLATFORM EMS DISAGREEMENT |
| 251602-5 | FUNCTION PREVENTED – EMS DISAGREEMENT |
| 3113-1 | OPEN CIRCUIT LINE CONTACTOR |
| 31163-1 | MAIN CONTACTOR COIL – SHORT TO BATTERY |
| 31203-1 | MAIN CONTACTOR COIL – SHORT TO GROUND OR OPEN CIRCUIT |
| 3213-2 | LINE CONTACTOR WELDED OR MISWIRED |
| 3223-2 | CONTACTOR DRIVER PERMANENTLY ON |
| 33113-3 | GROUND ALARM – SHORT TO BATTERY |
| 33123-3 | LEFT BRAKE – SHORT TO BATTERY |
| 33133-3 | RIGHT BRAKE – SHORT TO BATTERY |
| 33143-3 | LEFT BRAKE – OPEN CIRCUIT |
| 33153-3 | RIGHT BRAKE – OPEN CIRCUIT |
| 331003-3 | JIB LIFT UP VALVE – SHORT TO GROUND |
| 331013-3 | JIB LIFT UP VALVE – OPEN CIRCUIT |
| 331023-3 | JIB LIFT UP VALVE – SHORT TO BATTERY |
| 331033-3 | JIB LIFT DOWN VALVE – SHORT TO GROUND |
| 331043-3 | JIB LIFT DOWN VALVE – OPEN CIRCUIT |
| 331053-3 | JIB LIFT DOWN VALVE – SHORT TO BATTERY |
| 331823-3 | LIFT VALVES – SHORT TO BATTERY |
| 333543-3 | STEER VALVE – SHORT TO BATTERY |
| 333553-3 | STEER VALVE – SHORT TO GROUND |
| 333563-3 | STEER VALVE – OPEN CIRCUIT |
| 333583-3 | FLOW DIRECTION VALVE – SHORT TO GROUND |
| 333593-3 | FLOW DIRECTION VALVE – OPEN CIRCUIT |
| 333603-3 | SWING VALVE – SHORT TO BATTERY |
| 333623-3 | SWING VALVE – OPEN CIRCUIT |
| 333633-3 | MAST VALVE – SHORT TO BATTERY |
| 333653-3 | MAST VALVE – OPEN CIRCUIT |
| 333663-3 | PROPORTIONAL RELIEF VALVE – SHORT TO BATTERY |
| 333673-3 | PROPORTIONAL RELIEF VALVE – SHORT TO GROUND |
| 333683-3 | PROPORTIONAL RELIEF VALVE – OPEN CIRCUIT |
| 334173-3 | LIFT VALVES – SHORT TO GROUND or OPEN CIRCUIT |
| 334693-3 | MAST VALVE – SHORT TO GROUND |
| 337473-3 | AMBIENT ALARM – SHORT TO BATTERY |
| 337483-3 | AMBIENT ALARM – SHORT TO GROUND |
| 338253-3 | LEFT POWER MODULE MOTOR CURRENT – OUT OF RANGE |
| 338263-3 | RIGHT POWER MODULE MOTOR CURRENT – OUT OF RANGE |
| 338293-3 | COIL SUPPLY FAULT |
| 338403-3 | ALERT BEACON – SHORT TO BATTERY |
| 338413-3 | ALERT BEACON – SHORT TO GROUND |
| 338423-3 | ALERT BEACON – OPEN CIRCUIT |
| 4214-2 | POWER MODULE TOO HOT – PLEASE WAIT |
| 42104-2 | RIGHT DRIVE MOTOR TOO HOT – PLEASE WAIT |
| 42114-2 | LEFT DRIVE MOTOR TOO HOT – PLEASE WAIT |
| 42124-2 | RIGHT DRIVE MOTOR TEMPERATURE – OUT OF RANGE |
| 42134-2 | LEFT DRIVE MOTOR TEMPERATURE – OUT OF RANGE |
| 42204-2 | POWER MODULE TEMPERATURE – OUT OF RANGE |
| 42364-2 | TRACTION POWER MODULE TOO COLD – MODULE SHUTDOWN |
| 44174-4 | BATTERY POWER LOW |
| 44204-4 | BATTERY DEEPLY DISCHARGED |
| 44214-4 | LOGIC SUPPLY OUT OF RANGE |
| 44244-4 | POWER MODULE VOLTAGE TOO LOW – MODULE SHUTDOWN |
| 44254-4 | POWER MODULE VOLTAGE TOO HIGH – MODULE SHUTDOWN |
| 44734-4 | POWER MODULE VOLTAGE TOO LOW – REDUCED OPERATION |
| 44744-4 | POWER MODULE VOLTAGE TOO HIGH – REDUCED OPERATION |
| 441364-4 | BATTERY CHARGER – FAULT (SPN:FMI) |
| 441374-4 | BATTERY CHARGER – HIGH BATTERY VOLTAGE ERROR |
| 441384-4 | BATTERY CHARGER – BATTERY VOLTAGE TOO LOW FOR CHARGE |
| 441394-4 | BATTERY CHARGER – CHARGE TIMOUT OCCURRED |
| 441414-4 | BATTERY CHARGER – AMP HOUR LIMIT EXCEEDED |
| 441424-4 | BATTERY CHARGER – BATTERY TEMPERATURE SENSOR OUT OF RANGE |
| 441434-4 | BATTERY CHARGER – BATTERY VOLTAGE POLARITY REVERSED |
| 441444-4 | BATTERY CHARGER – ALGORITHM NOT SET |
| 441474-4 | BATTERY CHARGER – AC SUPPLY VOLTAGE TOO HIGH |
| 441484-4 | BATTERY CHARGER – AC SUPPLY VOLTAGE TOO LOW |
| 441494-4 | BATTERY CHARGER – BATTERY TEMPERATURE SENSOR NOT INSTALLED |
| 441504-4 | BATTERY CHARGER – BATTERY DISCONNECTED |
| 441564-4 | POWER MODULE LOGIC VOLTAGE – INCORRECT AT POWER ON |
| 4694-6 | VEHICLE OVERSPEED |
| 46124-6 | RIGHT SPEED SENSOR – RPM HIGH |
| 46134-6 | LEFT SPEED SENSOR – RPM HIGH |
| 46164-6 | BRAKES DID NOT LOCK |
| 461664-6 | DRIVE MOTOR TEMPERATURE SENSOR – NOT SELECTED |
| 461674-6 | LEFT MOTOR SPEED SENSOR – INVALID READING |
| 461684-6 | RIGHT MOTOR SPEED SENSOR – INVALID READING |
| 461704-6 | LEFT MOTOR SPEED SENSOR – NOT RESPONDING |
| 461714-6 | RIGHT MOTOR SPEED SENSOR – NOT RESPONDING |
| 461734-6 | LEFT MOTOR SPEED SENSOR – WRONG DIRECTION |
| 461744-6 | RIGHT MOTOR SPEED SENSOR – WRONG DIRECTION |
| 461834-6 | RIGHT MODULE – SPEED SENSOR FEEDBACK STAGNANT |
| 461844-6 | LEFT MODULE – SPEED SENSOR FEEDBACK STAGNANT |
| 462064-6 | RIGHT DRIVE MOTOR – NOT STOPPED |
| 462074-6 | LEFT DRIVE MOTOR – NOT STOPPED |
| 6616-6 | CANBUS FAILURE – POWER MODULE |
| 6626-6 | CANBUS FAILURE – PLATFORM MODULE |
| 66136-6 | CANBUS FAILURE – EXCESSIVE CANBUS ERRORS |
| 66496-6 | CANBUS FAILURE – TILT/TEMP SENSOR |
| 66546-6 | CANBUS FAILURE – LEFT MODULE |
| 66556-6 | CANBUS FAILURE – RIGHT MODULE |
| 661116-6 | CAN BUS FAILURE – CONNECTIVITY MODULE |
| 6726-7 | FUNCTIONS CUTOUT – SOFT TOUCH DETECTED |
| 6736-7 | FUNCTIONS CUTOUT – GATE OPEN DETECTED |
| 6826-8 | FUNCTIONS IN CREEP – CONNECTIVITY INTERLOCK |
| 6836-8 | FUNCTIONS IN CREEP AND RESTRICTED TO TRANSPORT – CONNECTIVITY INTERLOCK |
| 6846-8 | FUNCTIONS LOCKED OUT – CONNECTIVITY INTERLOCK |
| 6856-8 | ALL FUNCTIONS LOCKED OUT – CONNECTIVITY INTERLOCK |
| 6866-8 | ENGINE START PREVENTED – CONNECTIVITY INTERLOCK |
| 77127-7 | LEFT DRIVE MOTOR – OPEN CIRCUIT |
| 77157-7 | RIGHT DRIVE MOTOR OPEN CIRCUIT |
| 77327-7 | STALLED LEFT MOTOR |
| 77337-7 | STALLED RIGHTMOTOR |
| 77377-7 | PUMP MOTOR OVERLOADED |
| 77807-7 | POWER MODULE – CAPACITOR BANK FAULT |
| 77857-7 | LEFT MOTOR BRAKING IMPAIRED |
| 77867-7 | RIGHT MOTOR BRAKING IMPAIRED |
| 8138-1 | CHASSIS TILT SENSOR NOT CALIBRATED |
| 8148-1 | CHASSIS TILT SENSOR OUT OF RANGE |
| 8188-1 | TILT SENSOR STAGNANT |
| 8298-2 | FUNCTIONS CUTOUT – PLATFORM OVERLOADED |
| 82108-2 | OVERLOAD SENSOR ERROR |
| 86648-6 | STEER SENSOR – OUT OF RANGE HIGH |
| 86658-6 | STEER SENSOR – OUT OF RANGE LOW |
| 86668-6 | STEER SENSOR – DECOUPLED |
| 86678-6 | STEER SENSOR – NOT RESPONDING |
| 86688-6 | STEER SENSOR – NOT CALIBRATED |
| 8738-7 | MACHINE SAFETY SYSTEM OVERRIDE OCCURED |
| 9959-9 | POWER MODULE FAILURE – PERSONALITY RANGE ERROR |
| 9969-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 9979-9 | POWER MODULE FAILURE – CHECK POWER CIRCUITS OR MOSFET SHORT CIRCUIT |
| 9999-9 | FUNCTIONS LOCKED OUT – POWER MODULE SOFTWARE VERSION IMPROPER |
| 99109-9 | FUNCTIONS LOCKED OUT – PLATFORM MODULE SOFTWARE VERSION IMPROPER |
| 99129-9 | POWER MODULE FAILURE – SYSTEM MONITOR |
| 99209-9 | PLATFORM SENSOR REF VOLTAGE OUT OF RANGE |
| 99249-9 | FUNCTIONS LOCKED OUT – MACHINE NOT CONFIGURED |
| 99499-9 | MACHINE CONFIGURATION OUT OF RANGE – CHECK ALL SETTINGS |
| 99509-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99519-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99539-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99579-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99609-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 99709-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 991499-9 | POWER MODULE FAILURE – INTERNAL ERROR |
| 991629-9 | EEPROM FAILURE POWER MODULE – CHECK ALL SETTINGS |
| 991669-9 | DRIVE COMMAND ERROR |
| 991679-9 | PUMP COMMAND ERROR |
| 991689-9 | MASTER MODULE – CURRENT MEASUREMENT ERROR |
| 991699-9 | SLAVE MODULE – CURRENT MEASUREMENT ERROR |
| 992819-9 | FUNCTIONS LOCKED OUT – IMPROPER MOTOR PARAMETERS |
| 992869-9 | TRACTION MODULE – MOTOR PARAMETERS NOT CALIBRATED |
| 993659-9 | BATTERY CHARGER – FAILURE |
Source: Toucan 8E, 10E, 20E, 26E Service and Maintenance Manual (PVC 2607), Section 10 – Diagnostic Trouble Codes, no. 31210602 (2026-07-13). Codes and their meaning can vary with the serial number: always check your machine's manual. PDF JLG Toucan 10E manuals
Code keeps coming back, or the machine will not work?
Request service10.10 m working height (platform at 8.10 m) and 3.38 m working outreach.
200 kg: 2 people, indoors and outdoors (wind up to 12.5 m/s).
2,980 kg (CE version), 0.99 m wide and 1.99 m high stowed.
The Toucan 10E has a jib and rotating turntable, so it reaches over obstacles and several points without moving the base; a scissor lift only goes straight up but has a bigger platform.
The price is on request: it depends on the configuration (options, tyres, accessories) and delivery. Ask Trapézio de Prismas, the official JLG dealer in Portugal, for a quote.
The JLG Toucan 10E operation, service and parts manuals are in our JLG manuals library, by serial number. You can also request genuine parts from the same page.
Articulating boom lifts
Narrow (1.22 m) 11 m electric articulating boom lift with JibPLUS® jib, for indoors and tight aisles.
Articulating boom lifts
Diesel articulating boom lift with jib, for up-and-over reach on site.
Articulating boom lifts
Electric articulating boom lift, quiet and emission-free, for indoors and finished floors.
Get in touch. You will get a fast answer from people who know the machines.